DxxU Series

Information about the system

The DxxU Series, featuring D06U, D08U, D10U and D12U, offers lid integratable climate systems.

DescriptionDetailsMiscellaneous

These units are made to be integrated in the lids of DESAPRO or Zarges transport boxes.

They can also be operated when stacked. System control works via simple thermostats and via a remote or an internal controller.
They are future-proof thanks to easily replaceable components.

The power supply is to be provided from the respective case.

Just like our other lid air conditioning units, the DxxU systems collect heat energy generated during operation in the transport case, dissipate it to the outside and allow cooled or heated air to flow back in if necessary.

Alternative names for devices of this type include;  air conditioning cover insert/slide-in , cover insert climate unit, cover insert/slide-in air conditioner, cover insert air conditioner, insert / slide-in for air conditioners or insert/slide-in for case air conditioners.

Color: RAL6031 F9 or HR or according to customer specifications
Scope of delivery: 1 device

DxxU - Modell D10U

DxxU – Model D10U, prior to insertion

DxxU – Model D10U, front, rear

Designation D06U, D08U, D10U, D12U
Measures W*D*H in mm W: 525
D and H are lid/enclosure dependent
Weight in kg ~28 – ~62 (lid/compressor dependent)
Power supply  240V, 50Hz/60Hz
Environment air -40°C to +55/60°C
system is air cooled
Produced cold air  20 to 30°C
Refrigerant R134a
Amount device dependent
Cooling capacity 800W to 2.500W
Cooling operation +10°C to +55°C
Principle Direct evaporation
Heating 730W to 1.600W
Heating operation  -40°C to +10°C
Application range: Mobil, for integration within lids of DESAPRO, ZARGES and the likes
Intended climate: Desert, tropics, optionally  maritime
Lacquered/coated As per MIL standards, per Customers specifications or unpainted (Standard)
Case flanging Size dependent, hinge or bayonet lock
Optionals Partial-load, unloaded start, current limiting, operation with UPS and/or generator
 
The DxxU series in detail

Art-Nr Cooling cap. Refrig. cap. For HE>= kg~
D06U06 2.730 Btu/h 800 W 6 28
D08U12 3.410 Btu/h 1.000W 8 30
D10U12 4.780 Btu/h 1.400W 10 40
D10U17 6.820 Btu/h 2.000W 10 42
D12U24 8.530 Btu/h 2.500W 12 44
D16U33 11.900 Btu/h 3.500W 16 58